Secondary Bus Enclosures

Seamless Power Connectivity for Medium Voltage Systems
In complex electrical systems, the link between components can be just as critical as the gear itself. SEG secondary bus enclosures provide nonsegregated medium voltage phase bus connectivity between switchgear, transformers, utility metering cabinets , and other high voltage assemblies—ensuring safe, stable, and scalable power flow.

Built for voltage classes from 5 to 38 kV, these rugged enclosures simplify layout planning, support expansion, and preserve the system integrity that mission critical projects require.

Connect Your Medium Voltage System With Confidence

  • Download Technical Specs and Layout Examples
  • Request a Project Review or Quote
  • Talk to a SEG Engineer

Built to Bridge High Voltage Power Systems

Every system is built to customer specifications and validated for clearance, bracing, and site constraints before production. SEG secondary bus enclosures are used to:

  • Connect adjacent or parallel gear in substations
  • Route medium voltage bus between buildings or structures
  • Extend service from a transformer to switchgear lineups
  • Enable modular expansions for growing power needs
  • Facilitate utility to customer interconnects
Electrician inspecting high voltage electrical panel.

Technical Standards and Ratings

Our designs accommodate top or bottom cable entry and meet minimum bend radius and clearance requirements for medium voltage installations. All SEG bus enclosures meet or exceed:

  • ANSI C37.20.3 for medium voltage switchgear
  • Voltage classes from 600 V to 38 kV
  • Short circuit ratings up to 40 kA
  • BIL ratings of 60, 95, or 150 kV
  • NEMA 3R for outdoor exposure
  • IBC seismic qualification (optional)
  • Fully insulated or air-insulated copper bus systems

Build More Capacity Without Slowing the Job

When transformers reach their limits or site loads change late in the project, redesign is not an option. You need a secondary bus solution that installs cleanly, passes inspection, and keeps crews moving. Our 600 V secondary bus enclosures are built for contractors and EPC teams who need reliable equipment on tight timelines. Each unit is engineered to simplify installation, support load growth, and deliver proven performance in demanding environments.:

  • High conductivity copper bus for efficient connections
  • Two-hole NEMA lug provisions for secure, low-loss terminations
  • Rugged NEMA 3R outdoor-rated construction
  • Open bottom and open bus arrangements for fast cable access
  • Heavy-duty welded steel for long service life
Amps Bus Size Dimensions Part Number
2300 (2) 1/4 × 5 48"T × 36"W × 36"D PESB-0600-DD-2300-MS
2800 (2) 1/4 × 6 54"T × 42"W × 42"D PESB-0600-DD-2800-MS
3400 (3) 1/4 × 5 54"T × 48"W × 48"D PESB-0600-DD-3400-MS
4500 (4) 1/4 × 6 54"T × 54"W × 54"D PESB-0600-DD-4500-MS
5300 (4) 1/4 × 6 54"T × 60"W × 60"D PESB-0600-DD-5300-MS
6200 (5) 1/4 × 6 54"T × 66"W × 66"D PESB-0600-DD-6200-MS
7500 (6) 1/4 × 6 54"T × 66"W × 66"D PESB-0600-DD-7500-MS

Rugged Construction and Protection

Designed for long-term field service with minimal maintenance, each enclosure includes:

  • Welded 11-gauge steel bodies with reinforced corners
  • Powder coat finish or stainless steel for corrosion resistance
  • Padlockable three point latching doors
  • Isolated bus compartments and internal supports
  • Prepunched entry points or field adjustable flanges
  • Conduit landing plates and removable gland plates
Electrical control panels in industrial setting

Custom and Standard Layouts

We work from one line diagrams and site plans to deliver exactly what your system demands. SEG supports both quick-ship and engineered-to-order units:

  • Horizontal or vertical bus layouts
  • Side-by-side or above-ground routing
  • Removable covers or hinged door access
  • Multi-section configurations for long runs or dual feeds
  • Transition cabinets for utility tie-ins or multiple gear types

Safety and Testing

Our assemblies are designed with safety in mind. Optional arc flash sensors and coordination planning is also available.

  • Insulated bus options and phase separation
  • Internal barriers and touch safe access points
  • Infrared inspection ports and grounding provisions
  • Ground and test connections for verification
  • Full mechanical and electrical inspection prior to shipment
Technician uses multimeter on electrical panel.

Applications

Wherever continuity of power between gear is critical, SEG delivers the bridge.

Support Beyond the Equipment

Every project includes full documentation and as-built verification.

  • Application engineering and layout support
  • Coordination with switchgear and transformer interfaces
  • Site specific documentation and layout drawings
  • Installation guidance and field service coordination
  • Quick-ship options for emergency replacement or upgrade

More Products We Offer

Low-Voltage Switchboards

Low Voltage Equipment

Low-Voltage Switchboards

Medium Voltage Equipment

Custom Panelboards

Custom
Solutions

Industrial Custom Control Services

Control Panels & Services

Knowledge Base

Custom-Built Power Distribution Equipment

Request a quote today for reliable electrical power distribution and control equipment-
efficient, safe, and built to last!